Pulmonary function testing looks simple from the outside: the patient blows into a mouthpiece and a number appears. In practice, the number is only as good as the technologist behind it. Coaching a tired or anxious patient through a full effort, recognizing a poor maneuver, and knowing when a result doesn't make sense are skills that come from experience and ongoing learning.
Good pulmonary function technologist courses help with all of it:
Our self-paced PFT Boot Camp Part 1 and Part 2 are built around this kind of practical, clinic-ready knowledge.
A flawed test can mislead a diagnosis, so quality control is where good labs separate themselves. It starts with the equipment: daily calibration checks with a syringe, attention to leaks, and regular verification that sensors are working. Many labs also run biological controls to catch drift over time. Infection control between patients protects everyone.
Then comes the test itself. Spirometry has acceptability and repeatability standards, and a technologist who understands them knows when to ask for another effort and when to stop. Patient coaching matters just as much. Clear instructions, encouragement, and attention to technique often make the difference between a usable test and a questionable one.
Continuing education keeps these practices current, since professional standards are updated from time to time.
Spirometry shows how air moves, but it can't tell you everything. Lung volume testing measures how much air the lungs actually hold, including the portion that spirometry can't capture. Labs use body plethysmography, nitrogen washout, or helium dilution, and each has strengths and limits depending on the patient.
Diffusion capacity (DLCO) shows how well gas moves across the lung into the blood. It is sensitive to things outside the lungs too, such as hemoglobin level and carboxyhemoglobin, which is why technologists need to know when and how to account for them. It is also technique-dependent, so breath-hold timing and equipment checks matter.
Pulmonary function CEUs that cover these tests make it easier to produce results the interpreting physician can trust.
Technologists don't diagnose, but understanding what the results suggest makes you better at the job. In obstructive diseases such as asthma or COPD, airflow is limited, and the ratio of FEV1 to FVC falls. Restrictive patterns suggest reduced lung volume, but spirometry alone can't confirm it. Lung volume testing is needed to know for sure. Mixed patterns happen too.
Bronchodilator testing compares results before and after medication to see whether airflow improves. The criteria for a significant response come from published guidelines, so it is worth reviewing the current standards. Quality matters here as well, since poor technique on either test can hide or exaggerate a response.
For related reading, see our asthma courses.
If you hold the CPFT or RPFT credential, continuing education is part of keeping it. Requirements are set by the National Board for Respiratory Care (NBRC) and can change, so review their current credential maintenance rules on nbrc.org before you plan.
When choosing pulmonary function CEUs, confirm the course is AARC approved and lists its contact hours. Check our State Requirement guide for your board's rules, and log your hours in the CEU Tracker. You can also explore free CEUs, join a live webinar, or choose unlimited CEUs for year-round access.
1. What skills can pulmonary function technologists develop through continuing education?
Continuing education builds skills in patient coaching, test technique, equipment calibration and quality control, understanding spirometry, lung volumes, and diffusion testing, and recognizing common disease patterns. It also helps you keep up with changing standards.
2. How can continuing education help technologists improve the accuracy of pulmonary function test results?
Education reinforces the habits behind good data: calibration checks, leak detection, proper patient instruction, and knowing when a maneuver meets acceptability and repeatability criteria. It also helps you spot results that look wrong so they can be repeated or flagged.
3. What should pulmonary function technologists learn about interpreting spirometry results?
Learn the key measures, such as FVC, FEV1, and the FEV1/FVC ratio, and how they differ in obstructive and restrictive patterns. Also understand reference values, what makes a test acceptable, and why a reduced FVC alone doesn't confirm restriction. Interpretation is the physician's role, but a technologist who understands results produces better tests.
4. How can pulmonary function CEUs help professionals understand lung volume and diffusion capacity testing?
Pulmonary function CEUs explain how lung volumes are measured by plethysmography, nitrogen washout, or helium dilution, and what DLCO shows about gas exchange. They also cover factors that affect results, such as hemoglobin, carboxyhemoglobin, and breath-hold technique.
5. What are the key quality control practices in pulmonary function testing?
Daily calibration checks, leak testing, verifying sensors, running biological controls, cleaning and infection control between patients, and applying acceptability and repeatability criteria to every test. Good documentation helps catch problems early.
6. How can pulmonary function technologists improve their understanding of bronchodilator response testing?
Review how pre- and post-bronchodilator tests are performed, what changes in FEV1 and FVC are considered significant under current guidelines, and how technique and timing affect the comparison. Poor effort on either test can mislead the result.
7. Which continuing education topics are useful for professionals working with patients who have obstructive or restrictive lung diseases?
Useful topics include asthma and COPD, interstitial and other restrictive conditions, reading flow-volume loops, lung volume and diffusion findings, and how disease patterns show up on testing. Our asthma courses are a helpful companion.
8. How can pulmonary function technologists choose CEU courses that support their professional development and credential maintenance?
Confirm the course is AARC approved, check the contact hours, and choose topics that match your lab's work. Review the NBRC's current rules for maintaining your CPFT or RPFT credential, and check our State Requirement guide if your state has its own requirements.
Copyright © 2026 A&T Respiratory Lectures All Rights Reserved